Product Placeholder

Altivar 18

Repair Options

✓  Standard:  2-3 days

✓  Urgent:  24-48 hours*

✓  Service Exchange:  48-hour replacement*

✓  Spare Unit:  Same unit as the original*

* Services subject to availability

About

The Altivar 18 is a compact Telemecanique variable speed controller for asynchronous motors.

The range splits into two supply families across 17 references and five mechanical sizes. M2 covers 200-240 V single phase from 0.37 to 2.2 kW and 200-230 V three phase from 3 to 7.5 kW. N4 is 380-460 V three phase only, from 0.75 to 15 kW. Output runs 0.5 to 320 Hz, switching frequency is adjustable from 2.2 to 12 kHz, and transient current is 150 per cent of the controller nominal current for 60 seconds.

Schneider discontinued the range on 1 November 2020 and names the Altivar 320 as the replacement. Two details save time on an inbound unit: fan life is put at 3 to 5 years, which every surviving drive has long passed, and the top blanking cover is a self-adhesive film, so a unit arriving without it is set to IP20 and a 50 degrees C ambient rather than damaged.

Key Features

  • Output frequency 0.5 to 320 Hz, and 40 to 320 Hz nominal with a special motor

  • Switching frequency adjustable from 2.2 to 12 kHz

  • 150% of the controller nominal current for 60 seconds

  • Braking torque 30% of nominal motor torque, or up to 150% with the optional brake resistor

  • Motor thermal protection by integrated I2t calculation

  • IP31, or IP20 with the top blanking cover removed, which also lifts the permitted ambient from 40 to 50 degrees C

Range Specifications

ManufacturerTelemecanique (Schneider Electric)
SeriesAltivar 18
Power Supply VoltageSingle phase: 200 V -15% to 240 V +10%; 3-phase: 200 V -15% to 230 V +10%; 380 V -15% to 460 V +10%
Power Supply Frequency50/60 Hz ± 5%
Output VoltageMaximum voltage equal to mains voltage
Output Frequency Range0.5 to 320 Hz
Motor Power Range (Models Listed Below)0.37 to 15 kW (0.5 to 20 HP)
Permanent Output Current (Models Listed Below)2.1 to 29.3 A
Maximum Transient Current150% of speed controller nominal current for 60 seconds
Braking Torque30% of the nominal motor torque without brake resistor (typical value). Up to 150% with brake resistor as an option
Frequency ResolutionDisplay: 0.1 Hz; Analog inputs: 0.1 Hz for 100 Hz maximum
Switching FrequencyCan be adjusted from 2.2 to 12 kHz
Degree Of ProtectionIP31; IP20 without the blanking cover on the top
Vibration And Shock Resistance (EN50178)0.6 gn from 10 to 50 Hz; 2 gn from 50 to 150 Hz
Degree Of PollutionDegree 2 according to IEC664. Protect the speed controller from dust, corrosive gases, splashing liquid, etc.
Relative Maximum Humidity93% without condensation or dripping water. If there is a risk of condensation, provide a heating system
Ambient Air Temperature (EN50178)Storage: -25 °C to +65 °C. Operation: -10 °C to +40 °C without derating, with the blanking cover; -10 °C to +50 °C without derating, without the blanking cover
Maximum Operating Altitude1000 m without derating. Above this, derate the current by 3% for each additional 1000 m
Speed Controller Protection And SafetyElectrical isolation between power and control circuits (inputs, outputs, supplies); protection against short-circuits: internal supplies available, between output phases U - V - W, between the output phases and earth for ratings 5.5 to 15 kW; thermal protection from excessive overheating and overcurrents; under and overvoltage supply; overvoltage safe on braking
Motor ProtectionProtection integrated in the speed controller by calculating I2t
Product StatusDiscontinued on 1 November 2020 per Schneider Electric's ATV18 product pages; no end of service date is published. Schneider names the Altivar 320 as the replacement

Altivar 18 Models

Power supply voltage U1...U2 VLine current at U1 ALine current at U2 AMotor Power indicated on plate kWMotor Power indicated on plate HPPermanent output current AMaximum transient current APower dissipated at nominal load WReferenceWeight kg
200...240 50/60 Hz single phase4.43.90.370.52.13.123ATV-18U09M21.5
200...240 50/60 Hz single phase7.66.80.7513.65.439ATV-18U18M21.5
200...240 50/60 Hz single phase13.912.41.526.810.260ATV-18U29M22.1
200...240 50/60 Hz single phase19.417.42.239.614.478ATV-18U41M22.8
200...230 50/60 Hz 3-phase16.214.93-12.318.5104ATV-18U54M23.3
200...230 50/60 Hz 3-phase20.418.84516.424.6141ATV-18U72M23.3
200...230 50/60 Hz 3-phase28.726.55.57.52233200ATV-18U90M27.8
200...230 50/60 Hz 3-phase38.435.37.5102842264ATV-18D12M27.8
380...460 50/60 Hz 3-phase2.92.70.7512.13.224ATV-18U18N42
380...460 50/60 Hz 3-phase5.14.81.523.75.634ATV-18U29N42.1
380...460 50/60 Hz 3-phase6.86.32.235.3849ATV-18U41N43.1
380...460 50/60 Hz 3-phase9.88.43-7.110.769ATV-18U54N43.3
380...460 50/60 Hz 3-phase12.510.9459.213.894ATV-18U72N43.3
380...460 50/60 Hz 3-phase16.915.35.57.511.817.7135ATV-18U90N48
380...460 50/60 Hz 3-phase21.519.47.5101624175ATV-18D12N48
380...460 50/60 Hz 3-phase31.828.711152233261ATV-18D16N412
380...460 50/60 Hz 3-phase42.938.6152029.344342ATV-18D23N412

Figures are taken from the Telemecanique Altivar 18 User's manual, where line currents are typical values without additional inductance and the maximum transient current applies for 60 seconds; contact Inverter Drive Repair if the reference you hold does not appear above.