✓ Standard: 2-3 days
✓ Urgent: 24-48 hours*
✓ Service Exchange: 48-hour replacement*
✓ Spare Unit: Same unit as the original*
* Services subject to availability
The VACON NXS is the standard-performance member of the VACON NX platform. It shares power hardware, enclosure sizes, keypad and option boards with the higher-specification VACON NXP, but has no closed-loop vector mode, offering U/f and open-loop sensorless vector only, and its range stops at frame FR11 where the NXP continues to FR14.
Ratings run from 0.37 kW at high overload on 230 V to 560 kW at low overload on 690 V, each published twice, at 110 per cent up to 40 °C and 150 per cent up to 50 °C. Frames FR4 to FR9 are wall-mounted, FR10 and FR11 standalone.
The control unit has no fixed I/O: five slots, A to E, take a mix of basic, expander and fieldbus boards, so an input that appears dead may be a card or slot problem rather than a control-board failure. The snap-on cooling fan is the only regularly replaceable component. Danfoss lists the NXS in its active drives range.
0.37 kW to 560 kW, at supply voltages from 208 V to 690 V
U/f and open-loop sensorless vector control, in wall-mounted frames FR4 to FR9 and standalone FR10 to FR11
IP21/UL Type 1 and IP54/UL Type 12 enclosures, with an IP54 retrofit kit for FR4 to FR6
No fixed I/O: five slots, A to E, take basic, expander and fieldbus boards that can be added in the field
Integrated RFI filters, with EMC levels C1 to C4 selectable through the type code
Steady state speed error below 1%
Snap-on cooling fan, named as the only regularly replaceable component
| Manufacturer | Vacon |
|---|---|
| Series | VACON NXS |
| Power range | 0.37 kW (high overload, 230 V) to 560 kW (low overload, 690 V) |
| Supply voltages | 208-690 V |
| Voltage groups | 208-240 V; 380-500 V; 525-690 V |
| Enclosures | IP21/Type 1 and IP54/Type 12 |
| Control boards | Five slots for control boards (2 basic boards and 3 option boards) |
| Steady state speed error | < 1% |
| Acceleration / deceleration time | 0.1 to 3000 s (parameter setting range) |
| Product Status | Current: listed by Danfoss in the active VACON drives range |
| Series/voltage group | Model | Motor shaft power (10 percent overload), kW | Rated continuous current IL, A | Dimensions (W x H x D), mm |
|---|---|---|---|---|
| 208-240 V | NXS 0004 2A2H1SSS | 0.75 | 4.8 | 128x292x190 |
| 208-240 V | NXS 0007 2A2H1SSS | 1.1 | 6.6 | 128x292x190 |
| 208-240 V | NXS 0008 2A2H1SSS | 1.5 | 7.8 | 128x292x190 |
| 208-240 V | NXS 0011 2A2H1SSS | 2.2 | 11 | 128x292x190 |
| 208-240 V | NXS 0012 2A2H1SSS | 3 | 12.5 | 128x292x190 |
| 208-240 V | NXS 0017 2A2H1SSS | 4 | 17.5 | 144x391x214 |
| 208-240 V | NXS 0025 2A2H1SSS | 5.5 | 25 | 144x391x214 |
| 208-240 V | NXS 0031 2A2H1SSS | 7.5 | 31 | 144x391x214 |
| 208-240 V | NXS 0048 2A2H1SSS | 11 | 48 | 195x519x237 |
| 208-240 V | NXS 0061 2A2H1SSS | 15 | 61 | 195x519x237 |
| 208-240 V | NXS 0075 2A2H0SSS | 22 | 75 | 237x591x257 |
| 208-240 V | NXS 0088 2A2H0SSS | 22 | 88 | 237x591x257 |
| 208-240 V | NXS 0114 2A2H0SSS | 30 | 114 | 237x591x257 |
| 208-240 V | NXS 0140 2A2H0SSS | 37 | 140 | 291x758x344 |
| 208-240 V | NXS 0170 2A2H0SSS | 45 | 170 | 291x758x344 |
| 208-240 V | NXS 0205 2A2H0SSS | 55 | 205 | 291x758x344 |
| 208-240 V | NXS 0261 2A2H0SSF | 75 | 261 | 480x1150x362 |
| 208-240 V | NXS 0300 2A2H0SSF | 90 | 300 | 480x1150x362 |
| 380-500 V | NXS 0003 5A2H1SSS | 1.1 | 3.3 | 128x292x190 |
| 380-500 V | NXS 0004 5A2H1SSS | 1.5 | 4.3 | 128x292x190 |
| 380-500 V | NXS 0005 5A2H1SSS | 2.2 | 5.6 | 128x292x190 |
| 380-500 V | NXS 0007 5A2H1SSS | 3 | 7.6 | 128x292x190 |
| 380-500 V | NXS 0009 5A2H1SSS | 4 | 9 | 128x292x190 |
| 380-500 V | NXS 0012 5A2H1SSS | 5.5 | 12 | 128x292x190 |
| 380-500 V | NXS 0016 5A2H1SSS | 7.5 | 16 | 144x391x214 |
| 380-500 V | NXS 0022 5A2H1SSS | 11 | 23 | 144x391x214 |
| 380-500 V | NXS 0031 5A2H1SSS | 15 | 31 | 144x391x214 |
| 380-500 V | NXS 0038 5A2H1SSS | 22 | 38 | 195x519x237 |
| 380-500 V | NXS 0045 5A2H1SSS | 22 | 46 | 195x519x237 |
| 380-500 V | NXS 0061 5A2H1SSS | 30 | 61 | 195x519x237 |
| 380-500 V | NXS 0072 5A2H0SSS | 37 | 72 | 237x591x257 |
| 380-500 V | NXS 0087 5A2H0SSS | 45 | 87 | 237x591x257 |
| 380-500 V | NXS 0105 5A2H0SSS | 55 | 105 | 237x591x257 |
| 380-500 V | NXS 0140 5A2H0SSS | 75 | 140 | 291x758x344 |
| 380-500 V | NXS 0168 5A2H0SSS | 90 | 170 | 291x758x344 |
| 380-500 V | NXS 0205 5A2H0SSS | 110 | 205 | 291x758x344 |
| 380-500 V | NXS 0261 5A2H0SSF | 132 | 261 | 480x1150x362 |
| 380-500 V | NXS 0300 5A2H0SSF | 160 | 300 | 480x1150x362 |
| 380-500 V | NXS 0385 5A2L0SSA | 200 | 385 | 595x2018x602 |
| 380-500 V | NXS 0460 5A2L0SSA | 250 | 460 | 595x2018x602 |
| 380-500 V | NXS 0520 5A2L0SSA | 250 | 520 | 595x2018x602 |
| 380-500 V | NXS 0590 5A2L0SSA | 315 | 590 | 794x2018x602 |
| 380-500 V | NXS 0650 5A2L0SSA | 355 | 650 | 794x2018x602 |
| 380-500 V | NXS 0730 5A2L0SSA | 400 | 730 | 794x2018x602 |
| 525-690 V | NXS 0004 6A2L0SSS | 3 | 4.5 | 195x519x237 |
This table lists the first 45 models in the range. The kW figure is the motor shaft power at 10 percent overload (low overload duty, 40 degrees C ambient) and the current is the matching rated continuous current IL. Vacon publishes a second, higher overload rating for each unit, which is not listed here. Contact us if your unit is not listed and we will confirm it.