✓ Standard: 2-3 days
✓ Urgent: 24-48 hours*
✓ Service Exchange: 48-hour replacement*
✓ Spare Unit: Same unit as the original*
* Services subject to availability
The ZETADYN 2CF is the asynchronous half of Ziehl-Abegg’s second-generation lift drive pair, alongside the synchronous ZETADYN 2SY. It is a complete unit: an IGBT power section, a control board carrying the travel-curve computer, an integral mains choke, a type FEF radio interference filter and two motor contactors.
Those contactors are the one part that can be left out; the G build omits them. Eight sizes cover 13 A to 74 A, about 5.5 kW to 37 kW at 400 V, in S4 and G4 builds, with overload of 1.8 times rated current for ten seconds. The 2CF takes sine-wave encoders of 1024 to 8192 increments per revolution, or HTL and TTL encoders of 1024 to 2048.
Ambient rating is 0 to 40 degrees C, extending to 55 degrees C at a quarter of rated power, which is tighter than the ZETADYN 3 and 4 generations that followed, so do not assume a like-for-like thermal envelope when specifying a replacement.
Field-oriented closed-loop control for asynchronous lift machines
Full rated motor torque available at standstill
Overload to 1.8 times rated current for a maximum of 10 seconds
Integral line reactor with 4 per cent short-circuit voltage and a type FEF interference filter
Available with integrated motor contactors (S build) or without them (G build)
Sine-wave encoders of 1024 to 8192 increments, or HTL and TTL of 1024 to 2048
| Manufacturer | ZIEHL-ABEGG |
|---|---|
| Series | ZETADYN 2CF, for asynchronous motors (S4 and G4 type ranges) |
| Motor rated current | Up to 74 A |
| Rated terminal voltage | 3~ 400 V (absolute +10/-15 %) |
| Network form | TT, TN |
| Mains frequency | 50 / 60 Hz ±1.5 Hz |
| Nominal power for sizes 013 / 017 / 023 / 032 / 037 / 046 / 062 / 074 † | 5.5 / 7.5 / 11 / 15 / 18.5 / 22 / 30 / 37 kW |
| Nominal current, 60 % duty cycle, 8 kHz switching frequency † | 13 / 17 / 23 / 32 / 37 / 46 / 62 / 74 A |
| Nominal current, 60 % duty cycle, 12 kHz switching frequency † | 11* / 15* / 20* / 27 / 31 / 39 / 53 / 63 A |
| Nominal current, 60 % duty cycle, 16 kHz switching frequency † | 10* / 13* / 17* / 24 / 28 / 35 / 46 / 55 A |
| Max. operating current for 10 s † | 24 / 31 / 42 / 58 / 67 / 83 / 112 / 134 A |
| Overload capability | Maximum 10 s by a factor of up to 1.8 |
| Switching frequency note | At a switching frequency above 8 kHz a brake chopper of type BC25 must generally be used |
| Power loss (system at standstill) | 60 W |
| Power loss at 240 journeys per hour † | Less than 0.3 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.9 / 1.1 kW |
| Mains fuses (anti-surge) † | 16 / 20 / 25 / 35 / 50 / 50 / 63 / 80 A |
| Min. conductor size, motor cable † | 2.5 / 4 / 4 / 6 / 10 / 10 / 16 / 25 mm2 |
| Min. conductor size, brake chopper cable | 6 mm2 |
| Permissible ambient temperature in operation | 0 to 40 °C; above 40 °C with a power reduction of 1.66% per 1 K temperature rise; maximum 55 °C with a power reduction of 25% |
| Storage and transport temperature | -20 to +60 °C |
| Height of installation above sea level | Up to 1000 m; above 1000 m with a power reduction of 1% per 100 m of height; maximum 2000 m |
| Protection class (DIN 40050, IEC 144) | IP 20; requirements of VBG 4 are fulfilled |
| Relative humidity | 90 %; condensation not permitted |
| Dimensions (H x W x D) † | 600 x 358 x 190 mm and 730 x 358 x 251 mm (two enclosure variants) |
| Installation clearances | Minimum 50 mm at each side, minimum 100 mm above and below; mount the controller vertically with the cable connection terminals at the bottom |
| Control inputs | Current consumption typically 25 mA per input; voltage between +24 V and GND unstabilised 20 to 24 V DC |
| Relay outputs | Contact rating 230 V AC / 2 A at cos phi greater than 0.4; minimum switching duty 12 V / 2 mA |
| Auxiliary contacts, motor contactors | Minimum switching duty 17 V / 5 mA |
| Speed encoder | Maximum frequency 500 kHz (10,000 pulses per revolution, 3000 min-1). A sine wave encoder with a resolution of 1024 to 8192 increments per revolution, or an HTL or TTL encoder with 1024 to 2048 increments per revolution, should be used |
| Motor PTC connection P1-P2 | Motor temperature monitoring for PTC thermistor to DIN 44 081; a fault is triggered with a resistance at P1/P2 greater than 3.6k ohm |
| EMC and RFI suppression | Tested to IEC 801-4; RFI suppression to DIN EN 55011 Part 11 (Class B limit) using a type FEF RFI filter. To comply with Class B limits the motor cable must be screened and must not be longer than 10 m |
| Sound pressure level (fan in operation) | Sizes 013, 017, 023: typically 50 dB(A); 032, 037, 046: typically 49 dB(A); 062, 074: typically 52 dB(A). The English revision of the manual instead quotes only 52 dB(A) for inverter size 2CF / 2SY 110 |
| Product Status | Obsolete. The ZETADYN 2 generation does not appear in Ziehl-Abegg's 2025 elevator drive catalogue, which lists only ZAdyn4C, ZAdynpro and ZAdyn4Bplus |
† These electrical, loss and dimensional figures come from the manufacturer's joint ZETADYN 2CF / 2SY appendix A1 data table, reconstructed from two independent mirrors of the manual which agree on every value. Please confirm them against the documentation supplied with your own unit before relying on them. Values marked * are the small enclosure variant. Figures apply to sizes 013 to 074; the larger 110 A frame has its own manual and is not covered here.
| Umrichter-Typ 2CF (Converter type 2CF) | Artikel-Nr. (Part No.) |
|---|---|
| ZETADYN 2CF013S4 * | 352141 |
| ZETADYN 2CF017S4 * | 352142 |
| ZETADYN 2CF023S4 * | 352143 |
| ZETADYN 2CF032S4 | 352104 |
| ZETADYN 2CF037S4 | 352105 |
| ZETADYN 2CF046S4 | 352106 |
| ZETADYN 2CF062S4 | 352107 |
| ZETADYN 2CF074S4 | 352108 |
| ZETADYN 2CF013G4 * | 352119 |
| ZETADYN 2CF017G4 * | 352120 |
| ZETADYN 2CF023G4 * | 352121 |
| ZETADYN 2CF032G4 | 352114 |
| ZETADYN 2CF037G4 | 352115 |
| ZETADYN 2CF046G4 | 352116 |
| ZETADYN 2CF062G4 | 352117 |
| ZETADYN 2CF074G4 | 352118 |
Type code: the number is the nominal current in amps (013 = 13 A through to 074 = 74 A), 4 denotes the 400 V rated voltage, S is the version with motor contactors and G the version without. Values marked * are the small enclosure variant. The larger ZETADYN 2CF110B4 frame has its own separate manual and is not listed here, so please contact us with the type designation from your unit and we will confirm support for it.