The AVy-L is the lift version of SIEI’s AVy field-oriented vector drive, sold as ARTDriveL and later SIEIDrive-LIFT, and applies to both geared and gearless systems. The firmware is fixed at order time rather than by parameter: AC and AC4 units control asynchronous induction motors in field-oriented, sensorless vector or advanced V/f mode, while BR and BR4 units control synchronous brushless motors.
Twenty frame sizes run from 1007 at 0.75 kW to 81600 at 160 kW at 400 V, all on one input class of 230 V minus 15 per cent to 480 V plus 10 per cent, three-phase. Overload is quoted in elevator terms: 1.83 times continuous current for 10 seconds up to frame 4371.
The regulation card is what identifies an AVy-L in practice; its version can be read from the nameplate or from the label on the FLASH memories on the card, and is worth recording before a unit is stripped.
Field-oriented, sensorless vector and advanced V/f control on the AC and AC4 firmware, brushless control on the BR and BR4
Twenty frame sizes from 0.75 to 160 kW at 400 V on a single 230 to 480 V three-phase input class
Overload of 1.83 times continuous current for 10 seconds on frames up to 4371
Lift sequence with brake, output contactor and door control, plus pre-torque from a weight sensor at start
Landing control through an internal position regulator, with two independent S ramps and four jerk settings
IP20 as standard, IP54 for the cabinet with externally mounted heatsink on sizes 1007 to 3150
| Manufacturer | Gefran |
|---|---|
| Series | AVy-L (SIEIDrive LIFT / ARTDriveL), variants AVy...-AC, AVy...-AC4, AVy...-BR and AVy...-BR4 |
| Power range | 0.75 to 160 kW motor rating at 400 Vac |
| Maximum output frequency | 400 Hz (referred to regulation in field oriented mode) |
| Switching frequency | Default 8 kHz on smaller sizes and 4 kHz on larger sizes; higher setting 12 or 16 kHz on smaller sizes and 8 kHz on larger sizes |
| Switching frequency derating | Factor 0.7 at 16 kHz and 0.85 at 12 kHz; 0.7 for any switching frequency above default |
| Braking | Internal braking IGBT unit standard on sizes 1007 to 4185 and optional on sizes 4220 to 5550, in both cases with an external resistor; sizes 6750 to 81600 take an optional external braking unit. Braking torque 150% |
| Ambient temperature | 0 to +40 °C (32 to +104 °F); +40 to +50 °C (+104 to +122 °F) with derating |
| Derating over 40 °C | Current reduction of 2% of rated output current per K, with the front plate removed; the ambient temperature factor KT is 0.8 at 50 °C |
| Installation altitude | Up to 1000 m (3280 feet) above sea level; above that, a current reduction of 1.2% applies for every additional 100 m (328 feet) |
| Degree of protection | IP20; IP54 for the cabinet with externally mounted heatsink, size types 1007 to 3150 |
| Installation location | Pollution degree 2 or better, free from direct sunlight, vibration, dust, corrosive or inflammable gases, fog, vapour, oil and dripped water; avoid saline environments |
| Air humidity in operation | 5% to 85%, 1 g/m3 to 25 g/m3, without moisture condensation or icing (class 3K3 as per EN 50178) |
| Standards | Clearance and creepage to EN 50178, UL 508C and UL 840, pollution degree 2; climatic conditions to IEC 68-2 parts 2 and 3; vibration to IEC 68-2 part 6; EMC to EN 61800-3:2004 |
| Approvals | CE, UL, cUL |
| Type | Inverter Output (IEC 146 class1), Continuous service [kVA] | PN mot @ ULN=230Vac fSW=default IEC 146 class 1 [kW] | PN mot @ ULN=400Vac fSW=default IEC 146 class 1 [kW] | PN mot @ ULN=460Vac IEC 146 class 1 [Hp] | I2N Rated output current @ ULN=230-400Vac fSW=default IEC 146 class 1 [A] | I2N Rated output current @ ULN=460Vac fSW=default IEC 146 class 1 [A] |
|---|---|---|---|---|---|---|
| 1007 | 1.6 | 0.37 | 0.75 | 1 | 2.4 | 2.1 |
| 1015 | 2.7 | 0.75 | 1.5 | 2 | 4 | 3.5 |
| 1022 | 3.8 | 1.1 | 2.2 | 3 | 5.6 | 4.9 |
| 1030 | 5 | 1.5 | 3 | 3 | 7.5 | 6.5 |
| 2040 | 6.5 | 2.2 | 4 | 5 | 9.6 | 8.3 |
| 2055 | 8.5 | 3 | 5.5 | 7.5 | 12.6 | 11 |
| 2075 | 12 | 4 | 7.5 | 10 | 17.7 | 15.4 |
| 3110 | 16.8 | 5.5 | 11 | 15 | 24.8 | 21.6 |
| 3150 | 22.4 | 7.5 | 15 | 20 | 33 | 28.7 |
| 4185 | 26.5 | 9 | 18.5 | 23 | 39 | 34 |
| 4220 | 32 | 11 | 22 | 30 | 47 | 40 |
| 4300 | 42 | 18.5 | 30 | 40 | 63 | 54 |
| 4370 | 55 | 22 | 37 | 50 | 79 | 68 |
| 5450 | 64 | 22 | 45 | 60 | 93 | 81 |
| 5550 | 79 | 30 | 55 | 75 | 114 | 99 |
| 6750 | 98 | 37 | 75 | 100 | 142 | 124 |
| 7900 | 128 | 55 | 90 | 125 | 185 | 160 |
| 71100 | 145 | 55 | 110 | 150 | 210 | 183 |
| 71320 | 173 | 75 | 132 | 150 | 250 | 217 |
| 81600 | 224 | 90 | 160 | 200 | 324 | 282 |
Gefran's own manual numbers three of these sizes two ways, 4220 or 4221, 4300 or 4301 and 4370 or 4371, using one number in its input table and the other in its output table. They are alternative designations for the same three ratings, not separate models. The AC input current rows, the maximum short circuit power row and the overload capability tables are published but are not reproduced here; contact us with your drive size and we will confirm them.