✓ Standard: 2-3 days
✓ Urgent: 24-48 hours*
✓ Service Exchange: 48-hour replacement*
✓ Spare Unit: Same unit as the original*
* Services subject to availability
The 584S is a Eurotherm Drives frequency inverter for speed control of three-phase induction motors. Constant torque and quadratic torque are selectable in software on the same hardware, so one drive covers industrial duty and pump or fan duty at two power ratings, with overloads of 150 per cent for 60 s and 110 per cent for 10 s.
Chassis types 4 to 7 run from 0.75 kW to 75 kW constant torque and 1.1 kW to 90 kW quadratic, on a 208-240 V or 380-460 V three-phase supply. Types 8, 9 and 10 are 380-460 V only and reach 315 kW constant torque and 355 kW quadratic.
The eleven-block product code on the rating label always encodes the constant torque rating in block 2, so an 11 kW quadratic drive is coded 0075 and reads as 7.5 kW. Sizing from the label alone gets that wrong on every quadratic-duty machine. Parker labels the 584S a legacy product.
Constant torque and quadratic torque ratings selectable in software from the same hardware
Chassis types 4 to 10, covering 0.75 kW to 315 kW constant torque
Selectable maximum output frequency of 120 Hz, 240 Hz or 480 Hz
Option cards for serial communications, closed loop speed control and dynamic braking
Eight preset speeds, four skip frequencies and adjustable 50 to 150% current limit
Five stopping modes, including injection braking and FRAMP fast ramp
| Manufacturer | Eurotherm Drives (now Parker Hannifin, via SSD Drives) |
|---|---|
| Series | 584S, chassis types 4, 5, 6, 7, 8, 9 and 10 |
| Supply voltage | 3 phase mains supply with voltages of either 208 V to 240 V or 380 V to 460 V ±10%, 50/60 Hz. Chassis types 8, 9 and 10 are 380 V to 460 V only |
| Power range (constant torque) | 0.75 kW (1 hp) to 75 kW (100 hp) on chassis types 4 to 7; 90 kW to 315 kW on types 8, 9 and 10 |
| Power range (quadratic torque) | 1.1 kW (1.5 hp) to 90 kW (120 hp) on chassis types 4 to 7; 110 kW to 355 kW on types 8, 9 and 10 |
| Output frequency | 0-120, 240 or 480 Hz (selectable); chassis types 8, 9 and 10 are 0 to 120 Hz |
| Switching frequency | 3, 6 or 9 kHz (selectable) for power ratings up to 7.5 kW; 3 or 6 kHz (selectable) for power ratings from 11 kW to 75 kW; 3 kHz only for power ratings above 75 kW, and 3 kHz for every quadratic torque rating |
| Output overload (constant torque) | 150% for 60 s |
| Output overload (quadratic torque) | 110% for 10 s |
| Output voltage (max) | Input voltage |
| Current limits | 50 to 150% adjustable; 180% shock load limit |
| Voltage/frequency profile | Constant torque; fan law (base frequency adjustable) |
| Voltage boost | 0-25% (selectable auto or manual) |
| Preset speeds | 8 |
| Skip frequencies | 4 |
| Stopping modes | Ramp; ramp and DC holding pulse; injection braking; coast; FRAMP fast ramp |
| Protection (trip conditions) | Short circuit line to line; short circuit line to earth; overcurrent above 220%; I x t overload 50 to 105% (adjustable); heatsink overtemperature; motor thermistor overtemperature; overvoltage; undervoltage |
| Temperature range (constant torque) | 0 to 50 °C (0 to 40 °C for 2.2 kW 380-460 V); Type 7: 0 to 50 °C at 3 kHz, 0 to 45 °C at 6 kHz. Quadratic torque is 0 to 40 °C, and 0 to 35 °C with the UL Type 1 option fitted |
| Protection degree | IP20 on chassis types 4 to 7; types 8, 9 and 10 are IP20 enclosure with IP00 power terminals |
| Earth leakage current | Greater than 50 mA AC; permanent protective earthing required. Chassis types 8, 9 and 10 are >>100 mA and must be permanently earthed |
| Product Status | Legacy product, Parker's own label for both 584S manuals. Inverter Drive Repair offers inspection, repair and service exchange |
| Rating set / Input Voltage | Product Code Block 2 | Power (kW) | Input Current (A) | Output Current (A) |
|---|---|---|---|---|
| Constant torque 380-460V | 0007 | 0.75 | 3.0 | 2.3 |
| Constant torque 380-460V | 0011 | 1.1 | 4.5 | 3.3 |
| Constant torque 380-460V | 0015 | 1.5 | 6.0 | 4.5 |
| Constant torque 380-460V | 0022 | 2.2 | 8.0 | 6.3 |
| Constant torque 380-460V | 0040 | 4.0 | 11 | 9.4 |
| Constant torque 380-460V | 0055 | 5.5 | 15 | 13 |
| Constant torque 380-460V | 0075 | 7.5 | 18 | 16 |
| Constant torque 380-460V | 0110 | 11 | 25 | 24 |
| Constant torque 380-460V | 0150 | 15 | 31 | 30 |
| Constant torque 380-460V | 0180 | 18 | 40 | 39 |
| Constant torque 380-460V | 0220 | 22 | 46 | 46 |
| Constant torque 380-460V | 0300 | 30 | 61 | 61 |
| Constant torque 380-460V | 0370 | 37 | 72 | 72 |
| Constant torque 380-460V | 0450 | 45 | 91 | 91 |
| Constant torque 380-460V | 0550 | 55 | 110 | 110 |
| Constant torque 380-460V | 0750 | 75 | 150 | 150 |
| Constant torque 208-240V | 0007 | 0.75 | 5.5 | 4.3 |
| Constant torque 208-240V | 0011 | 1.1 | 7.5 | 6 |
| Constant torque 208-240V | 0015 | 1.5 | 9.5 | 8 |
| Constant torque 208-240V | 0022 | 2.2 | 12 | 10.5 |
| Constant torque 208-240V | 0040 | 4.0 | 19 | 17 |
| Constant torque 208-240V | 0055 | 5.5 | 25 | 24 |
| Constant torque 208-240V | 0075 | 7.5 | 31 | 30 |
| Constant torque 208-240V | 0110 | 11 | 46 | 46 |
| Constant torque 208-240V | 0150 | 15 | 61 | 61 |
| Constant torque 208-240V | 0180 | 18 | 72 | 72 |
| Constant torque 208-240V | 0220 | 22 | 86 | 86 |
| Constant torque 208-240V | 0300 | 30 | 120 | 120 |
| Constant torque 208-240V | 0370 | 37 | 145 | 145 |
| Quadratic torque 380-460V | 0007 | 1.1 | 4.4 | 3.2 |
| Quadratic torque 380-460V | 0011 | 1.5 | 5.8 | 4.0 |
| Quadratic torque 380-460V | 0015 | 2.2 | 7.0 | 5.4 |
| Quadratic torque 380-460V | 0022 | 3.0 | 9.5 | 7.1 |
| Quadratic torque 380-460V | 0040 | 5.5 | 14.5 | 13 |
| Quadratic torque 380-460V | 0055 | 7.5 | 18 | 16 |
| Quadratic torque 380-460V | 0075 | 11 | 24 | 22 |
| Quadratic torque 380-460V | 0110 | 15 | 31 | 29 |
| Quadratic torque 380-460V | 0150 | 18 | 38 | 36 |
| Quadratic torque 380-460V | 0180 | 22 | 47 | 45 |
| Quadratic torque 380-460V | 0220 | 30 | 61 | 59 |
This list is not complete. It shows the constant torque ratings for chassis types 4 to 7 on both supply voltages, and part of the 380-460 V quadratic torque set. The remaining quadratic torque 380-460 V ratings (product codes 0300, 0370, 0450, 0550 and 0750), all quadratic torque 208-240 V ratings, and every chassis type 8, 9 and 10 rating are not shown here, so please contact us with the product code from your drive and we will confirm support for your unit.