vacon nxl

VACON NXL

Repair Options

✓  Standard:  2-3 days

✓  Urgent:  24-48 hours*

✓  Service Exchange:  48-hour replacement*

✓  Spare Unit:  Same unit as the original*

* Services subject to availability

About

The VACON NXL is the compact member of the Vacon NX platform, its type code expanding the name as NX Light. Ratings run from 250 W to 30 kW in five mechanical sizes, MF2 to MF6. The two smallest are IP20 with an optional external RFI filter; MF4 and larger are IP21 or IP54 with internal EMC filters as standard. Two voltage classes are offered, 208-240 V and 380-500 V.

Every rating is published twice, at 110 per cent overload up to 40 °C and 150 per cent up to 50 °C. Motor control is U/f or open-loop sensorless vector, with no closed-loop or encoder mode. Modbus RTU is built in.

Danfoss has placed the NXL in the Inactive lifecycle phase, so parts are the constraint rather than the technology. Type numbers 0003 5, 0004 5 and 0005 5 each exist in two frames with different currents, so the nameplate enclosure digit must be read before cross-referencing a replacement.

Key Features

  • 250 W to 30 kW in five mechanical sizes, MF2 to MF6

  • IP20 on MF2 and MF3, IP21 or IP54 on MF4 to MF6

  • Dual overload rating: 110% for one minute in ten at 40 °C, or 150% at 50 °C

  • Starting torque of 150% at low overload and 200% at high overload

  • Switching frequency of 1 to 16 kHz, factory default 6 kHz

  • Modbus RTU built in, with OPT-AA and OPT-AI expander boards and PROFIBUS or Modbus/TCP fieldbus boards

  • Internal brake chopper standard from MF3 upwards, with the brake resistor as an option

Range Specifications

ManufacturerVacon
SeriesVACON NXL
Power range250 W to 30 kW, with every type rated twice, at 110% and at 150% overload
Voltage groups380-500 V; 208-240 V
Protection classesIP20 on MF2 and MF3; IP21 or IP54 on MF4 to MF6
Switching frequency1 to 16 kHz, factory default 6 kHz
Control interfaceStandard control I/O with option to be extended. RS485 integrated as standard
Integrated as standardMF4 and larger have internal EMC filters and an integrated input module; the brake chopper is standard from MF3 up. On MF2 and MF3 the RFI filter is an external option, and MF2 has no brake chopper
Acceleration / deceleration time0.1 to 3000 s (parameter setting range)
Product StatusInactive: discontinued and no longer in production, with spare parts and service options no longer available from Danfoss

VACON NXL Models

Series/voltage groupModelCapacity, kWCurrent, ADimensions (W x H x D), mm
380-500 VNXL 0001 5C1 N00.551.960x130x150
380-500 VNXL 0002 5C1 N00.752.460x130x150
380-500 VNXL 0003 5C1 N11.13.384x220x172
380-500 VNXL 0004 5C1 N11.54.384x220x172
380-500 VNXL 0005 5C1 N12.25.484x220x172
380-500 VNXL 0003 5C*H11.13.3128x292x190
380-500 VNXL 0004 5C*H11.54.3128x292x190
380-500 VNXL 0005 5C*H12.25.6128x292x190
380-500 VNXL 0007 5C*H137.6128x292x190
380-500 VNXL 0009 5C*H149128x292x190
380-500 VNXL 0012 5C*H15.512128x292x190
380-500 VNXL 0016 5C*H17.516144x391x214
380-500 VNXL 0023 5C*H11123144x391x214
380-500 VNXL 0031 5C*H11531144x391x214
380-500 VNXL 0038 5C*H118.538195x519x237
380-500 VNXL 0046 5C*H12246195x519x237
380-500 VNXL 0061 5C*H13061195x519x237
208-240 VNXL 0002 2C1 N00.372.460x130x150
208-240 VNXL 0003 2C1 N10.753.784x220x172
208-240 VNXL 0004 2C1 N11.14.884x220x172
208-240 VNXL 0006 2C1 N11.56.684x220x172

Capacity is the low-overload rating at 380 V for the 380-500 V types and at 230 V for the 208-240 V types. In the MF4 to MF6 codes the enclosure digit is shown as *: it is 2 for IP21 and 5 for IP54. Note that NXL 0003 5, NXL 0004 5 and NXL 0005 5 each exist in two different frames, so read the enclosure digit from the nameplate. NXL 0002 2 is for single-phase supply only.

What we offer

✓  2-year warranty

✓  Fast service

✓  Experienced engineers

✓  Friendly customer service

✓  24/7 technical support

✓  Courier return service

✓  Global coverage

✓  Reliability

✓  Flexibility

✓  No fix no fee

✓  Low prices

✓  High quality