Unidrive Classic is the drive that established Control Techniques’ universal platform. Two supply classes were built: the 200 V to 240 V range covers 0.37 kW to 22 kW in sizes 1 to 3, and the 380 V to 480 V range covers 0.75 kW to 160 kW in sizes 1 to 5, with output current from 2.1 A to 300 A per unit.
A single unit runs any of the control modes: open loop V/Hz or sensorless vector, closed loop flux vector, and servo for brushless motors. Options plug in as UD modules for MODBUS, PROFIBUS-DP, INTERBUS S and DeviceNet, with UniSoft for commissioning.
In the model number, UNI is the prefix and the character after it gives the frame size, 1 to 5. Each size 5 unit is rated at 300 A and up to eight can be paralleled for 2400 A, so the only size 5 model number published is UNI5401 and any larger output is several of those together.
Universal platform: V/Hz, sensorless vector, closed loop flux vector and servo control in one drive
Frame sizes 1 to 5, 0.37 kW to 160 kW, across 200 V and 400 V supply classes
Maximum output frequency 2000 Hz in open loop, and 30,000 rpm maximum speed in closed loop
More than 700 parameters with nine pre-configured application macros
Internal braking transistor fitted as standard
UD option modules for MODBUS, PROFIBUS-DP, INTERBUS S and DeviceNet
| Manufacturer | Control Techniques |
|---|---|
| Series | Unidrive Classic, UNI series (the manufacturer names the product simply Unidrive) |
| Motor Types | Induction and servo motors |
| Model Sizes | Sizes 1 to 5, UNI1201 to UNI5401 |
| Model Variants | Standard, plus the LFT and VTC variants named in the Control Techniques EMC data sheets. Regeneration is an operating mode, not a model variant |
| 200 V Drive Ratings Supply | 200 V to 240 V ± 10% |
| 400 V Drive Ratings Supply | 380 V to 480 V ± 10% |
| Nominal Rating Range (Models Listed Below) | 0.37 to 160 kW (0.5 to 200 hp) |
| Output Current Range (Models Listed Below) | 2.1 to 300 A |
| Output Current Rating Conditions | The output currents are given for maximum 40 °C (104 °F) ambient and 3 kHz switching. Derating is required for higher switching frequencies, ambient temperatures above 40 °C (104 °F) and high altitudes |
| Size 5 Output Current | Multiples of 300 A output current with 120% overload, or multiples of 240 A with 150% overload |
| Product Status | Superseded. Nidec lists Unidrive Classic on its Superseded AC Drives index and publishes no documentation for it. Inverter Drive Repair still services these units |
| Voltage group | Model | Nominal rating kW (200V table) / @380V kW (400V table) | Nominal rating hp (200V table) / @460V hp (400V table) | Output current* (A) | Typical Input current (A) |
|---|---|---|---|---|---|
| 200V drive ratings (200V to 240V ±10%) | 1201 | 0.37 | 0.5 | 2.1 | 2.4 |
| 200V drive ratings (200V to 240V ±10%) | 1202 | 0.55 | 0.75 | 2.8 | 3.5 |
| 200V drive ratings (200V to 240V ±10%) | 1203 | 0.75 | 1 | 3.8 | 4.6 |
| 200V drive ratings (200V to 240V ±10%) | 1204 | 1.1 | 1.5 | 5.6 | 6.5 |
| 200V drive ratings (200V to 240V ±10%) | 1205 | 2.2 | 3 | 9.5 | 8.6 |
| 200V drive ratings (200V to 240V ±10%) | 2201 | 3 | 4 | 12 | 10.8 |
| 200V drive ratings (200V to 240V ±10%) | 2202 | 4 | 5 | 16 | 14.3 |
| 200V drive ratings (200V to 240V ±10%) | 2203 | 5.5 | 10 | 25 | 19.8 |
| 200V drive ratings (200V to 240V ±10%) | 3201 | 7.5 | 15 | 34 | 26 |
| 200V drive ratings (200V to 240V ±10%) | 3202 | 11 | 20 | 46 | 39 |
| 200V drive ratings (200V to 240V ±10%) | 3203 | 15 | 25 | 60 | 53 |
| 200V drive ratings (200V to 240V ±10%) | 3204 | 22 | 30 | 74 | 78 |
| 400V drive ratings (380V to 480V ±10%) | 1401 | 0.75 | 1 | 2.1 | 3.0 |
| 400V drive ratings (380V to 480V ±10%) | 1402 | 1.1 | 1.5 | 2.8 | 4.3 |
| 400V drive ratings (380V to 480V ±10%) | 1403 | 1.5 | 2 | 3.8 | 5.8 |
| 400V drive ratings (380V to 480V ±10%) | 1404 | 2.2 | 3 | 5.6 | 8.2 |
| 400V drive ratings (380V to 480V ±10%) | 1405 | 4 | 5 | 9.5 | 10.0 |
| 400V drive ratings (380V to 480V ±10%) | 2401 | 5.5 | 7.5 | 12 | 13.0 |
| 400V drive ratings (380V to 480V ±10%) | 2402 | 7.5 | 10 | 16 | 17.0 |
| 400V drive ratings (380V to 480V ±10%) | 2403 | 11 | 15 | 25 | 21.0 |
| 400V drive ratings (380V to 480V ±10%) | 3401 | 15 | 25 | 34 | 27 |
| 400V drive ratings (380V to 480V ±10%) | 3402 | 18.5 | 30 | 40 | 32 |
| 400V drive ratings (380V to 480V ±10%) | 3403 | 22 | 30 | 46 | 40 |
| 400V drive ratings (380V to 480V ±10%) | 3404 | 30 | 40 | 60 | 52 |
| 400V drive ratings (380V to 480V ±10%) | 3405 | 37 | 50 | 70 | 66 |
| 400V drive ratings (380V to 480V ±10%) | 4401 | 45 | 75 | 96 | 76 |
| 400V drive ratings (380V to 480V ±10%) | 4402 | 55 | 100 | 124 | 91 |
| 400V drive ratings (380V to 480V ±10%) | 4403 | 75 | 125 | 156 | 123 |
| 400V drive ratings (380V to 480V ±10%) | 4404 | 90 | 150 | 180 | 145 |
| 400V drive ratings (380V to 480V ±10%) | 4405 | 110 | 150 | 202 | 181 |
| 400V drive ratings (380V to 480V ±10%) | 5401 | 160 | 200 | 300** | 280 |
Model numbers are shown without the UNI prefix, and the 200 V and 400 V rating tables are combined so the voltage group column shows which table each row came from. UNI5401 is the only size 5 model number in the manufacturer's own literature; larger outputs are built by connecting size 5 units in parallel. Contact Inverter Drive Repair if you need a rating that does not appear above.
✓ 2-year warranty
✓ Fast service
✓ Experienced engineers
✓ Friendly customer service
✓ 24/7 technical support
✓ Courier return service
✓ Global coverage
✓ Reliability
✓ Flexibility
✓ No fix no fee
✓ Low prices
✓ High quality