About

The ADL300 is the lift inverter in Gefran’s SIEIDrive range. It is a field-oriented vector drive made for civil lifts rather than adapted from a general-purpose product, and its firmware covers geared machines with asynchronous motors, including open loop, as well as gearless permanent-magnet synchronous machines in closed loop with an incremental TTL or absolute SinCos encoder.

Three supply variants share the name. The ADL300-4 takes three-phase 230, 400 or 480 V and reaches 75 kW; the ADL300-2T takes three-phase 200 to 230 V up to 37 kW; the ADL300-2M takes single-phase 200 to 230 V up to 5.5 kW for home lifts. A is the Advanced form, B the Basic, and all are IP20.

It is physically split into a power section, P-ADL, and a regulation section, R-ADL. The two largest frames, the 5750-4 and the 5370-2T, have no internal braking unit, so an external BUy unit is part of the installed system rather than a missing spare.

Key Features

  • Speed control with Elevator Floor Control for direct arrival at the floor

  • Position control with Elevator Positioning Control and automatic learning of floor distances

  • Certified for contactorless operation to EN 81-20, SIL 3

  • Emergency single-phase power supply for floor return

  • DCP3, DCP4, CANopen and CANopen Lift CiA 417 interfaces to the lift controller

  • Compact size for machine room-less installations

Range Specifications

ManufacturerGefran
SeriesADL300 lift series
Voltage groupsADL300-2M (1 phase 200-230 V); ADL300-2T (3 phase 200-230 V); ADL300-4 (3 phase 230/400/480 V)
Power range1.1 to 75 kW across the published model listing
ApplicationAC lift drive series for gearless and geared elevator systems
Motor typesAsynchronous motors (open and closed loop); synchronous motors with absolute or incremental encoders
ProtocolsDCP3 and DCP4; CANopen; CANopen Lift CiA 417
Lift functionsControl in speed, control in position, direct approach, relevelling, short floor management, emergency single-phase power supply for floor return
BrakingInternal IGBT braking unit with external resistor, standard up to 55 kW on the ADL300-4 and 30 kW on the ADL300-2T; the 5750-4 and 5370-2T take an external braking unit
Operator interfaceIntegrated 1 line x 4 character alphanumerical LED keypad

Gefran ADL300 Models

Series/voltage groupModelCapacity, kWCurrent, ADimensions (W x H x D), mm
ADL300-2M lift series (1 phase 200-230 V)ADL300-1011-2M1.1Not published162x343x159
ADL300-2M lift series (1 phase 200-230 V)ADL300-1015-2M1.5Not published162x343x159
ADL300-2M lift series (1 phase 200-230 V)ADL300-2022-2M2.2Not published162x396x159
ADL300-2M lift series (1 phase 200-230 V)ADL300-2030-2M3Not published162x396x159
ADL300-2M lift series (1 phase 200-230 V)ADL300-3040-2M4Not published235x401x179.4
ADL300-2M lift series (1 phase 200-230 V)ADL300-3055-2M5.5Not published235x401x179.4
ADL300-2T lift series (3 phase 200-230 V)ADL300-2055-2T5.524.5162x396x159
ADL300-2T lift series (3 phase 200-230 V)ADL300-3075-2T7.532235x401x179.4
ADL300-2T lift series (3 phase 200-230 V)ADL300-3110-2T1145235x401x179.4
ADL300-2T lift series (3 phase 200-230 V)ADL300-4150-2T1560267.6x616x276
ADL300-2T lift series (3 phase 200-230 V)ADL300-4185-2T18.575267.6x616x276
ADL300-2T lift series (3 phase 200-230 V)ADL300-4220-2T2290267.6x616x276
ADL300-2T lift series (3 phase 200-230 V)ADL300-5300-2T30105311x767x331.4
ADL300-2T lift series (3 phase 200-230 V)ADL300-5370-2T37150311x767x331.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-1040-429162x343x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-1055-4313.5162x343x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-2075-4418.5162x396x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-2110-45.524.5162x396x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-3150-47.532235x401x179.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-3185-4939235x401x179.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-3220-41145235x401x179.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-4300-41560267.6x616x276
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-4370-418.575267.6x616x276
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-4450-42290267.6x616x276
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-5550-430105311x767x331.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 230 V mainsADL300-5750-437150311x767x331.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-1040-449162x343x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-1055-45.513.5162x343x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-2075-47.518.5162x396x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-2110-41124.5162x396x159
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-3150-41532235x401x179.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-3185-418.539235x401x179.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-3220-42245235x401x179.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-4300-43060267.6x616x276
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-4370-43775267.6x616x276
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-4450-44590267.6x616x276
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-5550-455105311x767x331.4
ADL300-4 lift series (3 phase 230/400/480 V), rating at 400 V mainsADL300-5750-475150311x767x331.4

The twelve ADL300-4 references appear twice, once with the motor rating Gefran publishes for a 230 V supply and once for 400 V. They are the same twelve drives: the ADL300-4 accepts 230, 400 or 480 V and the motor rating follows the supply. Output current for the single-phase ADL300-2M is not published in any Gefran or WEG document we hold. Send us your model number and supply voltage and we will confirm the correct rating.