About

MICROMASTER Vector, abbreviated MMV, is the sensorless vector member of the Siemens MICROMASTER family that preceded the MICROMASTER 4 range. It is the small end of a pairing with the larger MIDIMASTER Vector, an IP20 built-in unit covering 0.12 kW to 7.5 kW.

Siemens describes sensorless vector control as letting the inverter hold motor speed across a wide range of load conditions, giving high starting torque and accurate speed regulation without an encoder. Overload is 200 per cent for three seconds and then 150 per cent for sixty, output runs from 0 Hz to 650 Hz, and a built-in brake chopper takes an external resistor.

The supply arrangement decides which unit you have. Single phase 230 V models run to 3.0 kW, all with an integrated Class A filter. A separate 380-480 V filtered range ends in 50 rather than 40, so an order number quoted without its last two digits has not identified the drive.

Key Features

  • Sensorless vector control for high starting torque without an encoder

  • 200 % overload for 3 seconds, then 150 % for 60 seconds

  • Fast Current Limit (FCL) for trip-free operation

  • Built-in brake chopper for an external resistor, plus DC injection with compound braking

  • RS485 with USS protocol for up to 31 inverters

  • PID process control with a 15 V, 50 mA supply for the feedback transducer

Range Specifications

ManufacturerSiemens
SeriesMicromaster Vector (MMV)
Input voltage range (230 V models)1 AC 208-240 V ±10% (single phase); 1-3 AC 208-240 V ±10%
Input voltage range (400 V class)3 AC 380-500 V ±10% (filtered versions: 3 AC 380-480 V ±10%)
Input frequency47 Hz to 63 Hz
Output frequency range0 Hz to 650 Hz
Frequency resolution0.01 Hz
Motor output range (models listed below)0.12 kW to 7.5 kW
Overload capability200% for 3 s then 150% for 60 s (related to nominal current)
Regulation and controlSensorless vector; FCC (Flux Current Control); voltage/frequency curve
Analogue input / PID inputUnipolar: 0-10 V / 2-10 V; 0-20 mA / 4-20 mA; Bipolar: -10 to 0 to +10 V
Analogue setpoint resolution10-bit
Setpoint stabilityAnalogue less than 1%; Digital less than 0.02%
Motor temperature monitoringPTC input, I2t control
Ramp times0-650 s
Control outputs2 relays 230 V AC / 0.8 A (overvoltage cat.2); 30 V DC / 2 A
InterfaceRS485
Inverter efficiency97%
Operating temperature0 °C to +50 °C
Storage / transport temperature-40 °C to +70 °C
VentilationFan cooling (software controlled)
Humidity95% non-condensing
Installation height above sea levelLess than 1000 m
Degree of protectionIP20 (NEMA 1)
Power factor0.7 or greater
Operating mode4 quadrants possible (re-generation back into mains not possible)
Protection againstInverter overtemperature; overvoltage and undervoltage; short-circuits and earth/ground faults; pull-out protection; running with no load (open-circuit)
Product StatusObsolete. No Siemens lifecycle or phase-out notice has been located for this range

Micromaster Vector Models

Order No. (6SE32..)Inverter modelInput voltage rangeMotor output rating (kW/hp)Output current nom. (A)Output current max. continuous (A)Input current max. (A)
10-7BA40MMV121 AC 208-240 V0.12 / 1/60.750.91.8
11-5BA40MMV251 AC 208-240 V0.25 / 1/31.51.73.2
12-1BA40MMV371 AC 208-240 V0.37 / 1/22.12.34.6
12-8BA40MMV551 AC 208-240 V0.55 / 3/42.63.06.2
13-6BA40MMV751 AC 208-240 V0.75 / 13.53.98.2
15-2BB40MMV1101 AC 208-240 V1.1 / 1.54.85.511.0
16-8BB40MMV1501 AC 208-240 V1.5 / 26.67.414.4
21-0BC40MMV2201 AC 208-240 V2.2 / 39.010.420.2
21-3BC40MMV3001 AC 208-240 V3.0 / 411.813.628.3
10-7CA40MMV12/21-3 AC 208-240 V0.12 / 1/60.80.91.8 / 1.1
11-5CA40MMV25/21-3 AC 208-240 V0.25 / 1/31.51.73.2 / 1.9
12-1CA40MMV37/21-3 AC 208-240 V0.37 / 1/22.12.34.6 / 2.7
12-8CA40MMV55/21-3 AC 208-240 V0.55 / 3/42.63.06.2 / 3.6
13-6CA40MMV75/21-3 AC 208-240 V0.75 / 13.53.98.2 / 4.7
15-2CB40MMV110/21-3 AC 208-240 V1.1 / 1.54.85.511.0 / 6.4
16-8CB40MMV150/21-3 AC 208-240 V1.5 / 26.67.414.4 / 8.3
21-0CC40MMV220/21-3 AC 208-240 V2.2 / 39.010.420.2 / 11.7
21-3CC40MMV300/21-3 AC 208-240 V3.0 / 411.813.628.3 / 16.3
21-8CC40MMV400/23 AC 208-240 V4.0 / 515.917.521.1
11-1DA40MMV37/33 AC 380-500 V0.37 / 1/21.21.22.2
11-4DA40MMV55/33 AC 380-500 V0.55 / 3/41.51.62.8
12-0DA40MMV75/33 AC 380-500 V0.75 / 12.02.13.7
12-7DA40MMV110/33 AC 380-500 V1.1 / 1.52.83.04.9
14-0DA40MMV150/33 AC 380-500 V1.5 / 23.74.05.9
15-8DB40MMV220/33 AC 380-500 V2.2 / 35.25.98.8
17-3DB40MMV300/33 AC 380-500 V3.0 / 46.87.711.1
21-0DC40MMV400/33 AC 380-500 V4.0 / 59.210.213.6
21-3DC40MMV550/33 AC 380-500 V5.5 / 7.511.813.217.1
21-5DC40MMV750/33 AC 380-500 V7.5 / 1015.817.522.1
15-8DB50MMV220/3F (built-in Class A filter)3 AC 380-480 V2.2 / 35.25.98.8
17-3DB50MMV300/3F (built-in Class A filter)3 AC 380-480 V3.0 / 46.87.711.1
21-0DC50MMV400/3F (built-in Class A filter)3 AC 380-480 V4.0 / 59.210.213.6
21-3DC50MMV550/3F (built-in Class A filter)3 AC 380-480 V5.5 / 7.511.813.217.1
21-5DC50MMV750/3F (built-in Class A filter)3 AC 380-480 V7.5 / 1015.817.022.1

Source footnotes: on the 400 V class models, output current ratings are reduced by 10% when operating on mains supply voltages over 460 V; Siemens prints that footnote against those tables only. Motor output ratings refer to a Siemens 4 pole motor, 1LA5 series or equivalent. All 1 AC 230 V Micromaster Vector units include integrated Class A filters. If your unit is not listed here, please contact us with the details from its rating plate.

What we offer